8100 and 8200 Monitors
Fixed Point Sludge Blanket Detection

The 8100 Monitor provides a reliable method of detecting the sludge blanket level in clarifiers and settlement tanks, or increasing levels of suspended solids or sludge density in a large range of processes. Control of the sludge blanket level is essential to ensure discharge consent compliance and efficient control of the treatment process. If the sludge blanket in a settlement tank is allowed to rise close to the surface there is a danger that solids will leave the tank and contaminate the next process stage or be discharged into the water course. Alternatively, if the sludge blanket is not allowed to stabilise or form a blanket or is pumped out too frequently the settlement process does not take place at all and solids will remain in suspension. Additionally there is a danger that thin sludge or water will be pumped from the bottom of the tank into the sludge handling system thus reducing the effectiveness of that process.

The 8100 Monitor is suitable for mounting outdoors on the bridge of settlement tanks, as the enclosure is IP65 rated and no outer enclosure is required. Provision must be made for transmission of the output signal to the control system; this is normally possible via spare slip rings. Where this is not possible a radio telemetry option is available, allowing transmission directly to the control system without the need for installation of cables.
The 8200 Monitor is a two channel version of the monitor providing the option of alarming at two positions in a tank or on two tanks that are located close together.
For information our Sludge Blanket sensors go to the sludge blanket sensor page.
Applications
- Final Settlement Tanks
- Clarifiers
- Primary Settlement Tanks
Features
- Simple Operation
- Low Cost of Ownership
- Alarm Output
Technical Specification
Physical
| Dimensions | 160 x 195 x 105 mm (HxWxD) |
| Weight | 1 kg |
| Protection Class | IP65 |
| Enclosure Material | ABS |
| Cable Entries | 4 x PG11 (cable 5 to 10 mm) |
| Cable Size | Max Conductor Size 2.5 mm² |
Environmental Data
| Operating Temperature | Electronics 0 to 50ºC |
| Storage Temperature | Electronics 0 to 50ºC |
| Location | Indoor or Outdoor |
Output Signals
| Analogue Output | None |
| Relays | 2 |
| Contacts | SPCO, 5A @ 230VAC, 5A @125 VDC |
User Interface
| Local Annunciation | 3 LED's , Green for Normal, Red for Blanket alarm, Amber for fault |
| Setup | Potentiometer and Push Buttons on main PCBA |
| Adjustment | 5 - 95% of sensor range |
Electrical
| Power Supply | 115/230VAC, +10/-15% Field Selectable |
| 24VDC option available | |
| Power Rating | 8W |
| Fuse | 100mA |
Measurement Characteristics
| Measurement Principle | Light Attenuation |
| Response Time | 1 to 90 seconds |

Download 8200 Datasheet
Download 8100/8200 FlexTech Monitor Bracket
Download 8100/8200 FlexTech Monitor Enclosure
Download 8100 and 8200 Manual
Download 8100/8200 User List

Share