8100 and 8200 Monitors

Fixed Point Sludge Blanket Detection

The 8100 Monitor provides a reliable method of detecting the sludge blanket level in clarifiers and settlement tanks, or increasing levels of suspended solids or sludge density in a large range of processes. Control of the sludge blanket level is essential to ensure discharge consent compliance and efficient control of the treatment process. If the sludge blanket in a settlement tank is allowed to rise close to the surface there is a danger that solids will leave the tank and contaminate the next process stage or be discharged into the water course. Alternatively, if the sludge blanket is not allowed to stabilise or form a blanket or is pumped out too frequently the settlement process does not take place at all and solids will remain in suspension. Additionally there is a danger that thin sludge or water will be pumped from the bottom of the tank into the sludge handling system thus reducing the effectiveness of that process.

The 8100 Monitor is suitable for mounting outdoors on the bridge of settlement tanks, as the enclosure is IP65 rated and no outer enclosure is required. Provision must be made for transmission of the output signal to the control system; this is normally possible via spare slip rings. Where this is not possible a radio telemetry option is available, allowing transmission directly to the control system without the need for installation of cables.

The 8200 Monitor is a two channel version of the monitor providing the option of alarming at two positions in a tank or on two tanks that are located close together.

For information our Sludge Blanket sensors go to the sludge blanket sensor page.

Applications

  • Final Settlement Tanks
  • Clarifiers
  • Primary Settlement Tanks

Features

  • Simple Operation
  • Low Cost of Ownership
  • Alarm Output

Technical Specification

Physical

Dimensions160 x 195 x 105 mm (HxWxD)
Weight1 kg
Protection ClassIP65
Enclosure MaterialABS
Cable Entries4 x PG11 (cable 5 to 10 mm)
Cable SizeMax Conductor Size 2.5 mm²

Environmental Data

Operating Temperature Electronics 0 to 50ºC
Storage Temperature Electronics 0 to 50ºC
Location Indoor or Outdoor

Output Signals

Analogue OutputNone
Relays2
ContactsSPCO, 5A @ 230VAC, 5A @125 VDC

User Interface

Local Annunciation3 LED's , Green for Normal, Red for Blanket alarm, Amber for fault
SetupPotentiometer and Push Buttons on main PCBA
Adjustment5 - 95% of sensor range

Electrical

Power Supply115/230VAC, +10/-15% Field Selectable
24VDC option available
Power Rating8W
Fuse100mA

Measurement Characteristics

Measurement PrincipleLight Attenuation
Response Time1 to 90 seconds