Partech Products SoliTechw² IL Sensor
SoliTechw² IL Sensors
In-Line Sensor for Monitoring Suspended Solids and Sludge Density

The SoliTechw² IL Sensor provides reliable and repeatable, continuous in-line measurement of sludge density, suspended solids and turbidity. The sensor is installed
through a mounting boss onto any pipeline that is larger than 65 mm diameter. The sensing element is positioned flush with the inside wall of the pipe, this ensures
that the optical surface is kept clean by the flow passing the sensor and that the sensor does not cause an obstruction to the flow. The optical element has a sapphire window,
this offers excellent resistance to fouling and to damage caused by the abrasion from particles in the flow.
The sensor is suitable for a variety of applications including the auto de-sludging of primary and final settlement tanks, where reliable sludge density measurement
ensures that downstream treatment processes can operate at their optimum level. When detecting turbidity the sensor can give immediate warning of a filter failure or
of contamination of a process by suspended particles. The sensor is also well suited to the monitoring of sludge at tanker intake points, giving an excellent indicator
of the strength of the incoming liquor allowing both process adjustments and the charges to be applied to the tanker operator.

The sensor uses infrared back-scatter at 960nm, the light is transmitted and received through a lens that is optically split. The infrared measurement principle allows
the sensor to work in applications where entrained air prevents the use of ultrasonic sensors.
Applications
- Returned Activated Sludge
Features
Technical Specification
Physical
| Dimensions | 392 mm long |
| Weight | 7.2 kg |
| Protection Class | IP68 |
| Material of Construction | Black Acetal Co-Polymer, 316 Stainless Steel, Sapphire |
| Seal Material | Nitrile |
| Cable Entries | Integral Cable Gland |
| Cable Type | 4 core, 2 Twisted Pair, 5mm O/D Polyurethane Coated |
| Cable Length | 10 metres standard, 100 metres maximum |
| Service Requirement | Sensor cleaning is required at a frequency determined by site charactersitics |
Environmental Data
| Operating Temperature | 0 - 50ºC |
| Storage Temperature | -20 to 60ºC |
| Location | Indoor or Outdoor |
| Pressure Rating | 2 Bar |
Interface to Monitor
| Sensor Output | ModTechw², RS485 |
| Power | 12 VDC from Monitor |
Measurement Principal
| Principal of Operation | Light Back Scatter |
| Wavelength | 960 nm Infrared |
Measurement Characteristics
| Accuracy | Better than +/- 5% Reading on real sample |
| Resolution | Dependent on rangesetting, typcially +/- 2% |
| Repeatability | Better than +/- 1% Reading on real sample |
| Response Time | 0.5 seconds - damping provided by monitor |
| Flowrate | Not affected by flowrate, avoid deadspots and extreme turbulence |
| Maximum Range | 0 - 50,000 mg/l or 0 - 5%SS |
| Minimum Range | 0 - 5,000 mg/l or 0 - 0.5%SS |
| Measuring range will depend on the nature of the sample being monitored |
Process Connection
| Normal Mounting | In-Line via Mounting Boss |
| Process Connection | 1 1/4" BSP Male |
| Minimm Line Size | 65 mm |
Information to Download