Turbi-Techw² LR Sensors
Self Cleaning Sensor for Turbidity Monitoring

The TurbiTechw² LR Sensor has been specifically designed to monitor final treated, portable and filter water. The sensor is extremely sensitive and is capable of discriminating
changes in Turbidity of less than 0.1 FTU. The 90º light scatter monitoring technique makes the sensor sensitive to a wide range of particle sizes, from colloidal material
through to larger particles and raw waters and the large mineral particles sometimes found in distribution samples.
The TurbiTechw² LR Sensor complies with the internationally recognised ISO7027 standard for Turbidity measurement. The unique sensor design captures stray light
which ensures an ultra stable zero point, this is combined with an automatic self-cleaning mechanism that prevent the build up of fouling within the sample chamber.
The measurement system includes a self monitoring loop that compensates for changes in optical performance.

The sensor requires very little maintenance, with no special tools or training required. Calibration can be carried out against either a wet Turbidity standard or using the dry calibration reference cell that is supplied with every sensor. The reference cell provide an extremely easy, repeatable method of checking the performance of the sensor without the cost and inherent errors associated with chemical standards.
Applications
- Final Water
- Filter Backwash Control
- Intake Protection
Features
- Automatic Self Cleaning
- Low Cost of Ownership
- Large Sample Volume
Technical Specification
Physical
| Dimensions | 440 mm x 200 mm x 200 mm (HxWxD) |
| Weight | 4.5 kg |
| Enclosure Rating | IP68 |
| Material of Construction | Black Acetal Co-Polymer, Polypropylene |
| Seal Material | Nitrile |
| Cable Entries | Integral Cable Gland |
| Cable Type | 4 core, 2 Twisted Pair, 5mm O/D Polyurethane Coated |
| Cable Length | 10 metres standard, 100 metres maximum |
| Process Connections | Inlet and Bypass: 1/2" BSP with 12 mm hosetail |
| Outlet: 1/4" BSP with 8 mm hosetail | |
| Service Requirement | Automatic Self Cleaning |
| Wiper and Dessicant Replacement yearly (application dependent) |
Environmental Data
| Operating Temperature | 0 - 50ºC |
| Storage Temperature | -20 to 60ºC |
| Location | Indoor |
Interface to Monitor
| Sensor Output | ModTechw², RS485 |
| Power | 12 VDC from Monitor |
Measurement Principal
| Principal of Operation | 90º Light Scatter |
Measurement Characteristics
| Accuracy | Better than +/- 2% Reading on real sample |
| Resolution | Dependent on range setting, typcially +/- 2% |
| Repeatability | Better than +/- 1% Reading on real sample |
| Response Time | 90% of step change in 2 minutes at 1 l/min |
| Flowrate | 0.5 to 5 l/minute |
| Low Range | 0-5 to 0-30 NTU |
| High Range | 0-50 to 0-500 NTU |
| It has been assumed that 1 FTU = 1 NTU for the purposes of this statement |

Download TurbiTechw² LR Specification
Download De-bubbler Datasheet
Download TurbiTechw² Manual