TurbiTechw² LS Sensors
Self Cleaning Sensor for Suspended Solids and Turbidity Monitoring

The TurbiTechw² LS Sensor is designed to monitor the levels of Suspended Solids or Turbidity typically found in Final Effluent from municipal and industrial wastewater
treatment plants. It is also capable of monitoring solids in the intake to both effluent and drinking water treatment processes. The normal operating range is between
0 - 50 and 0 - 500 FTU, a version of the sensor is available that extends the range to 0-1,000 FTU.
Monitoring of these key parameters requires sensors that are reliable and accurate, the TurbiTechw² LS fills this requirement perfectly. The large optical surfaces and
sample volume ensure that the information provided by the sensor is both representative of the process and tolerant of fouling. In addition the sensor incorporates a
self cleaning mechanism that ensures that the optical surfaces are kept clean at all times, the cleaning system is designed to avoid problems with ragging and does not
smear the optical system. The cleaning system ensures that manual intervention on a routine basis is not required, the sensor should simply be checked as part of general
site housekeeping.

The TurbiTechw² LS Sensor employs infrared light at 860 nm using the 90º Light Scatter principle in accordance with ISO7027 (2000). The cleaning process is automatically initiated by the 7300w² Monitor at a user determined frequency. The cleaning process takes only 90 seconds, which means that the sensor is available for 99.5% of the time with a 5 hourly cleaning cycle.
Applications
- Final Effluent Turbidity
- Dosing Control
- Intake Protection
Features
- Automatic Self Cleaning
- ISO 7027 Compliant
- Large Sample Volume
Technical Specification
Physical
| Dimensions | 80 mm diameter, 470 mm long |
| Weight | 2.2 kg |
| Protection Class | IP68 |
| Material of Construction | Black Acetal Co-Polymer, 316 Stainless Steel, Glass |
| Seal Material | Polyurethane, Nitrile (Optional Viton) |
| Cable Entries | Integral Cable Gland |
| Cable Type | 4 core, 2 Twisted Pair, 5mm O/D Polyurethane Coated |
| Cable Length | 10 metres standard, 100 metres maximum |
| Service Requirement | Seal Service every 3500 cleans (application dependent) |
Environmental Data
| Operating Temperature | 0 - 50ºC |
| Storage Temperature | -20 to 60ºC |
| Location | Indoor or Outdoor |
| Pressure Rating | 10 mWC |
Interface to Monitor
| Sensor Output | ModTechw², RS485 |
| Power | 12 VDC from Monitor |
Measurement Principal
| Principal of Operation | 90º Light Scatter |
| ISO 7027 Compliant | |
| Wavelength | 860 nm Infrared |
Measurement Characteristics
| Accuracy | Better than +/- 5% Reading on real sample |
| Resolution | Dependent on range setting, typcially +/- 2% |
| Repeatability | Better than +/- 1% Reading on real sample |
| Response Time | 0.5 seconds - damping provided by monitor |
| Flowrate | Not affected by flowrate, avoid deadspots and extreme turbulence |
| Maximum Range | 0-500 FTU, extended range 0-1,000 FTU available |
| Minimum Range | 0-50 FTU |
| Measuring range will depend on the nature of the sample being monitored |