Partech Products WaterTechw² C4E Sensor
WaterTechw² C4E Conductivity and Salinity Sensor
Combined Sensor for Conductivity, Salinity and Temperature Monitoring
The WaterTechw² C4E Sensor has been designed to provide highly reliable Conductivity, Salinity and Temperature measurements. The multi-range sensor allows the same sensor
to be employed in a wide variety of applications, the monitoring system being set up to provide the optimum accuracy and resolution for the intended application.
Conductivity is a broad measurement that indicates the level of dissolved minerals in the water, for process waters it is an indicator that the water purifier system is not
working. In some cases it can be used to prevent problems with scaling due to hardness of tap water, especially in boiler feed water. In many applications Conductivity can
be used as a measurement of Total Dissolved Solids (TDS) and is a useful general indicator of water quality.

For installation in applications where fouling is anticipated we recommend that the sensor is installed using our specially designed mounting system, with a flexible
joint in the mounting shaft. The flexible joint moves the sensor in the process, reducing bio-fouling and allowing rags to fall away from the assembly. This motion
is similar to that achieved by using a floating ball assembly, with the added advantage of placing the sensor below the surface of the liquid. In applications where
fouling is not expected or where there is insufficient space alternative mounting arrangements are available.
Applications
Features
- Combined Conductivity and Salinity
Technical Specification
Physical
| Dimensions | 27 mm diameter x 177 mm long |
| Weight | 0.35 kg |
| Protection Class | IP68 |
| Material of Construction | PVC Body,Stainless Steel |
| Cable Entries | Integral Cable Gland |
| Cable Type | 6 core, Polyurethane Coated |
| Cable Length | 10 metres standard, 100 metres maximum |
| Service Requirement | Periodic Cleaning and calibration are required at a frequency determined by the application |
Environmental Data
| Operating Temperature | -10 - 60ºC |
| Storage Temperature | 0 to 50ºC |
| Pressure Rating | 5 Bar |
| Location | Indoor/Outdoor |
Interface to Monitor
| Sensor Output | RS485 |
| Power | 12 VDC from Monitor |
Conductivity Measurement
| Principal of Operation | 4 Electrode (2 Graphite, 2 Platinum) |
| Accuracy | +/- 1% of FSD |
| Resolution | 0.01 to 1 depending on range |
| Range | 0 - 200 µS/cm to 0-200 mS/cm |
Salinty Measurement
| Principal of Operation | Calculated from Conductivity and Temperature |
| Range | 5 to 60 ppt (g/Kg) |
Temperature Measurement
| Temperature Measurements | NTC |
| Accuracy | +/- 0.5 ºC |
| Resolution | 0.01 ºC |
| Range | 0- 50 º |
Information to Download