WaterWatch2950

Organic Pollution and UV Transmissivity Monitoring System

The use of the absorption of ultraviolet light by organic material in water is a well established principle for monitoring organic load in many water and wastewater treatment processes. Careful consideration of the likely pollutants is required to ensure that the use of a ultraviolet wavelengths is the most appropriate for the application, we are more than happy to help with this assessment.

The WaterWatch2950 uses a high quality strobed light source combined with an integrated Turbidity interference removal algorithm. The light source is stable with a long life providing stable measurements with the minimum of user intervention. Careful design of the flow through sensor chamber reduces the likelihood of fouling and the sensor is equipped with an automatic self cleaning system to keep the optical path clear.

The output signal from the system can be used as surrogate measurement of COD, however a full understanding the the sample matrix is necessary to validate the measurement. Partech are happy to work with you to gain a full understanding of the process to be monitored.

Alternatively the system can be configured as a transmissivity monitor; in this configuration the output can be used to modulate the power output of UV treatment systems or to provide an alarm indicating that the UV treatment may not be as effective as desired.

Applications

  • Organic Pollution
  • UV Transmissivity
  • Intake Protection

Features

  • Automatic Self Cleaning
  • Low Cost of Ownership
  • Surrogare COD Monitor

Technical Specification

Physical - Monitor

Dimensions222 x 310 x 180 mm (HxWxD)
Weight2.5 kg
Protection ClassIP65
Enclosure MaterialABS
Cable Entries5x M13, 1xM20
Cable Core SizeMax Conductor Size 2.5 mm²

Electrical

Power Supply115/230 VAC

User Interface

Display4 Digit LED Measurement Display
2 Line LCD Message Display
Membrane Keypad5 Key pillow embossed
Units of Measurementmg/l C, %Transmissivity

Environmental Data

Operating Temperature 0 - 50ºC
Storage Temperature -20 to 50ºC
Location Indoor or in PProtective Outer Enclosure

Output Signals

Analogue Output4-20mA, max load 750 ohm
Relays2
Relay TypeSPCO
Relay Rating5A @ 230VAC, 5A@125VDC
TypeHigh, Low or Fault
Adjustment0-100% Sensor Range

Physical - Sensor

Dimensions405 mm x 373 mm x 136 mm (HxWxD)
Weight6.5 kg
Protection ClassIP68
Material of ConstructionBlack Acetal Co-Polymer, Polypropylene
Seal MaterialNitrile
Cable EntriesIntegral Cable Gland
Cable Type4 core, 5mm O/D Polyurethane Coated
Cable Length10 metres standard, 100 metres maximum
Process ConnectionsInlet and Bypass: 1/2" BSP with 12 mm hosetail
Outlet: 1/4" BSP with 8 mm hosetail
Service RequirementAutomatic Self Cleaning
Wiper and Dessicant Replacement yearly (application dependent)

Measurement Principal

Principal of OperationUV Attenuation
Light SourceXenon Strobe
Measured Wavelength254 nm
Turbidity Correction400 nm
Path Length4.9 mm
CalibrationTwo Point

Measurement Characteristics

AccuracyBetter than +/- 10% FSD
Resolution1 mg/l C
RepeatabilityBetter than +/- 1% FSD on real sample
Response Time90% of step change in 3 minutes at 1 l/min
Flowrate0.5 to 5 l/minute
Range0-100 to 0-500 mg/l C