The Turbi-Tech 2000HR Sensor has been specifically designed for use in wastewater treatment systems where high levels of suspended solids are desirable in the aeration phase. Membrane Bio Reactors (MBR’s) typically run with MLSS values in the region of 8,000 to 14,000 mg/l. MLSS concentrations promote numerous process benefits, including stable operation, complete nitrification, and reduced biosolids production reducing biological volume requirements (and associated footprint) to only 20-30 percent of conventional biological processes. Furthermore, the membrane tanks provide extremely space efficient solids separation and do not require a clarifier in the system.
The Turbi-Tech 2000HR sensor is suitable for monitoring solids in higher ranges than the standard LA version of the sensor due to it’s shorter path length. The large optical surface and sample volume combine to ensure that the sensor is providing information that is reliable and representative of the solids present in the process. Deposits of fats and grease on the sensing area do not prevent the sensor from measuring unlike sensors with small optical surfaces.
In addition the sensor incorporates a self cleaning mechanism that ensures that the optical surfaces are kept clean at all times, the cleaning system is designed to avoid problems with ragging and does not smear the optical system. The cleaning system ensures that manual intervention on a routine basis is not required, the sensor should simply be checked as part of general site housekeeping. The Turbi-Tech 2000HR Sensor uses Infrared Light at 860 nm and operates using the Light Attenuation Principle. The cleaning mechanism uses a polyurethane wiper seal, backed by 2 Nitrile ‘H’ Rings that finish the cleaning process. The Nitrile seals can be exchanged for Viton if the process media dictates. The cleaning process is automatically initiated by the 7200 Monitor at a user determined frequency. The cleaning process takes only 90 seconds, which means that the sensor is available for 99.5% of the time with a 5 hourly cleaning cycle.
Physical | |
---|---|
Dimensions (hxwxd) | Ø80mm, 470 mm long |
Weight | 2.2 kg |
Protection Class | IP68 |
Enclosure Material | Black Acetal Co-Polymer, 316 Stainless Steel, Glass |
Seal Material | Polyurethane, Nitrile, with option of Viton |
Cable Entry | Integral Cable Gland |
Cable Length | 10 metres standard, 100 metres maximum |
Interface to Monitor | |
Power Supply | 12 VDC from Monitor |
Sensor Output | PWM |
Environmental Data | |
Operating/Storage Temperature | 0 to 50ºC |
Location | Indoor/Outdoor |
Pressure Rating | 10 mWC |
Maintenance | |
Service | Seal Service every 3500 cleans (application dependent) |
Calibration | The sensor is inherently stable, calibration should be carried out to suit the application. Our recommendation is every 6 months. |
Measurement Characteristics | |
---|---|
Principal of Operation | Light Attenuation/Scatter |
Wavelength | 860 nm Infrared |
Accuracy | Better than +/-5% of reading on real sample |
Resolution | Dependent on range setting, typically +/-2% of reading |
Response Time | 0.5 seconds damping provided by monitor |
Flowrate | Not affected by flowrate, avoid deadspots and extreme turbulence |
Units | User Selectable mg/l, g/l, ppm, %SS, NTU |
Maximum Range | 0-30,000 mg/l |
Minimum Range | 0-10,000 mg/l |
The actual measuring range will depend on the nature of the sample being monitored, for processes normally operating at 10,000 mg/l or more should consider use of the HR version of this sensor. Processes that use carbon will provide higher than expected readings and the HR version of the sensor should be used. |
Part Number | Description |
---|---|
220600 | Turbi-Tech 2000HR Sensor (Cable Length: 10 metres, Nitrile Seals) |
222635 | Turbi-Tech 2000HR Sensor (Cable Length: 20 metres, Nitrile Seals) |
Mounting Shafts | |
152703 | FlexTech Mounting Shaft (TurbiTechw² LA/HR/LS, 1.0 metres) |
152701 | FlexTech Mounting Shaft (TurbiTechw² LA/HR/LS, 1.0 metres) |
152705 | FlexTech Mounting Shaft (TurbiTechw² LA/HR/LS, 1.0 metres) |
Mounting Brackets | |
223980 | FlexTech Sensor Bracket (Handrail Ø 43 to 60.3 mm) |
224567 | FlexTech Sensor Bracket Extension Assembly (500 mm Long, Handrail Ø 43 to 60.3 mm) |
Seal Service Pack | |
220607 | Seal Service Pack - Turbi-Tech 2000HR, TurbiTechw² HR, Nitrile H RIngs |
220608 | Seal Service Pack - Turbi-Tech 2000HR, TurbiTechw² HR, Viton H RIngs |
The 7200 Monitor combines with the Partech range of Suspended Solids and Turbidity Sensors
More DetailsInline Sensor for Sludge Density, Suspended Solids and Turbidity Monitoring
More DetailsSelf Cleaning Suspended Solids or Turbidity sensor designed for discharge and inlet monitoring
More DetailsSelf Cleaning sensor designed for use in aeration systems monitoring Suspended Solids also known as Mixed Liquor Suspended Solids or Activated Sludge
More Details